        Today, the editor of Jincheng air-conditioning manufacturer introduces the precautions for cooling tower selection.

   1. The structural material of the cooling towershould be stable, durable, corrosion-resistant, and accurate in assembly and coordination.

   2. The water distribution is even. The wall flow is less. The splashing device is selected reasonably, and it is not easy to be blocked.

   3. The type of cooling tower spray filler meets the requirements of water quality and water temperature.

4. The fan is matched to ensure long-term normal operation without vibration and abnormal noise, and the blades are resistant to water erosion and have sufficient strength. The installation angle of the fan blades is adjustable, but the angle must be consistent, and the current of the motor does not exceed the motor's Rated current.

    5. Low power consumption. Low cost. Small and medium-sized steel frame glass cooling towers also require light weight.

    6. Cooling towers should be avoided as far as possible to be placed near heat sources, waste gas and flue gas generating points, chemical storage places and coal piles.

        7. For the distance betweencooling tower or between towers and other buildings, in addition to considering the ventilation requirements of the tower and the mutual influence between the tower and the building, the fire protection of the building should also be considered. The explosion-proof safety distance and the construction and maintenance requirements of the cooling tower .

    8. The material of the cooling tower can withstand the low temperature of -50℃, but it should be stated when ordering the areas where the average temperature of the cold month is lower than -10℃, so that anti-icing measures can be taken. The cost of the cooling tower will increase by about 3%.  

         9. The direction of the water inlet pipe of the cooling tower can be rotated by 90°.180°.270°.

      10. The turbidity of the circulating water is not more than 50mg/l, and it should not contain oil and mechanical impurities in the short-term not more than 100mg/l. If necessary, measures to kill algae and stabilize water quality should be taken.

      11. The water distribution system is designed according to the nominal water volume. If the actual water volume differs from the nominal water volume by more than ±15%, it should be stated when ordering to modify the design.

     12. During the storage and transportation of cooling tower components, no heavy objects shall be placed on them, no exposure to the sun, and fire prevention. Cooling tower installation, transportation, and maintenance are not allowed to use electric, gas welding and other open flames, and firecrackers and fireworks are not allowed to be set off nearby.

     13. With multi-tower design for round towers, the net distance between towers should be no less than 0.5 times the diameter of the tower body. Cross-flow towers and counter-current square towers can be arranged side by side.

     14. The selected water pump should be matched with the cooling tower to ensure the flow rate, head and other process requirements.

       15. When choosing multiple cooling towers, use the same model as much as possible.

 Industrial air conditioning, chemical fiber industrial air conditioningchemical fiber industry refrigeration, textile industrial air conditioning, dust-free workshop coolingventilation pipeline, cooling tower, freezer and other air conditioning units and accessories.


  Jiangsu Jincheng Air Conditioning Engineering Co., Ltd. is a comprehensive manufacturer of special air-conditioning equipment design, production, installation, and commissioning of clean room, electricity, tobacco, civil air defense engineering, medical clean room, clean room, electricity, tobacco, civil air defense engineering, medical clean room. Mainly produce JCZK combined air conditioning unit, cooling tower, glass steel ventilated galvanized sheet pipe, stainless steel pipe, polyurethane ventilation pipe and air conditioning accessories, Jincheng air conditioner is wide, the type, the unique model, superior performance, and user Favused.


Keyword:
ADD:No. 18, Rongguang Road, National High-tech Park, Yancheng City, Jiangsu Province Phone: 0086-13705113637 Tell: 0086-0515-88809180 Fax: 0086-0515-88809181 E-Mail: jsjckt@126.com
Copyright ? 2018 All rights reserved
Copyright Jiangsu Jin Cheng Air Conditioning Engineering Co.,Ltd 技術(shù)支持:中國丙綸網(wǎng)