中国丰满熟妇xxxx性,被公侵犯怀孕的人妻中文字幕,国产成人无码精品亚洲,国产又爽又黄无码无遮挡在线观看

[How to choose textile industry air conditioners and teach you!]
Release date:[2022/4/28] Is reading[209]次

My country is a big textile country. In order to ensure that workers have a comfortable working environment, the textile industry will choose to install the textile industrial air conditioning,. Often, the textile plant has a problem on the choice of  textile industrial air conditioning. It can improve fiber performance and product quality, and can ensure the health of the producer. With the continuous improvement of the quality requirements of the market, more and more textile companies have paid more and more attention to the energy saving management of textile air. Therefore, you should understand these when choosing a textile industrial air conditioning,.


1. Reasonable design and layout of the textile factory air -conditioning equipment system

  After determining the type, power and air supply of the air conditioner, the design and layout of the air conditioning system will determine the energy consumption level. The position of the air-conditioned room should be selected to shorten the length of the air-to-air pipeline as much as possible, and the equal cross-section (the wind speed at the entrance of the wind room is 8-10 m / s) to design the airway return air pipe (for the economic wind speed speed (for the economic wind speed to The design of the wind speed at the trachea entrance is 7 meters/second) the design of the gas supply system and the reasonable setting of the air -wind speed to provide the possibility of the effective utilization efficiency of the air conditioner.


2. Reasonable selection of textile factories air -conditioning equipment

  Traditional air -conditioned rooms use ordinary bearing fan to provide air, and mainly rely on the spray system to achieve humidification. The humidification function of the new air -conditioning room is realized under the full -function air conditioning system. Under the deployment of the full -function air conditioning system, the spray shaft fans can not only meet the gas supply requirements, but also have a humidification function. The two cooperate with each other to achieve the three seasons of spring, autumn, and winter. Compared with the traditional air-conditioned room, energy saving can be energy-saving by 20-40 %. In summer, using low humidity or installation of a row of sprayers can save 10-15 % of energy. The average annual energy saving energy can reach about 30 %.

  It is understood that in the spinning workshop of a textile company in Shandong, the air -conditioning machine room system is equipped with a full -function air -conditioning system and equipped with XX spray shaft flowers. After commissioning, the relative humidity of the workshop is about 70 %, the temperature of the summer workshop is 26-28 ° C, and the temperature of the workshop in winter is 23-25 ° C. After the transformation, compared with the traditional spray air -conditioning system, energy can be saved by 20 % per year.


3. Reasonably select the air conditioning system equipment

  Instead, it is used to use a new type of spray axis flow fan, which reduces or eliminates the spray system and greatly reduces the energy consumption of the air conditioning room. A spinning company with 200,000 ingots in Shandong has 14 air -conditioning systems in its workshop. The FZ -type shaft fans in the 5 systems were transformed and the SZ energy -saving shaft fans were used. After the transformation, each typhoon can save 6.31 kilowatts with an average of 6.31 kW and 20.99 % of the power saving. Five sets of air -conditioning systems can save energy and save about 260,000 degrees.

  Most of the spray rooms of textile air -conditioning equipment use spin nozzles. The water droplets sprayed by nozzle have small droplets, large jet angles and lower jet pressure characteristics. Therefore, when choosing a pump, the pump should not be too high. The large 22-28 meters is a relatively reasonable range, trying to avoid the phenomenon of large buses and carts. By setting the reasonable length of the shower room, the heat exchange between the air and the atomized water curtain can be ensured, thereby further improving the capacity of the air conditioning.

  The air -to -air filter system can adopt a disc filter or rotating cage filter according to the specific situation of the workshop, and it can be reasonably set to the ground wind or side wall according to the needs of the workshop, or combined with two methods. Reasonable selection of air -to -air filter equipment can help the energy saving of air conditioners.


  4. The operation and management of the air -conditioning system

  Different production processes have different requirements for the temperature and humidity of the air -conditioning system. As we all know, the installed capacity of the workshop and the temperature and humidity of the workshop are the two main foundations of the design of textile air -conditioning systems. Therefore, determining the temperature and humidity suitable for process production requirements is essential for the configuration of the air supply of the air -conditioning system. According to the different types of workshop and production varieties, the temperature and humidity of air conditioning and the temperature and humidity of the air conditioner are reasonably set, which is not only conducive to improving product quality, but also has a positive effect on improving the efficiency of air conditioning.


  In addition, the air supply volume of textile air -conditioning equipment is determined according to the high temperature in summer. In other seasons, the amount of air delivery will be greater than the actual amount of air, which puts forward new requirements for the operation of the fan. Due to the successful application of the frequency conversion motor in the air conditioning system, the operation of the fan can be continuously changed, and the airback of the fan can be adjusted at any time.

  At present, according to the different needs of textile companies, the fan market is divided into different types of fans, such as shaft fans, centrifugal fan, dust fan, spray shaft fans and textile host fans. They are textile air conditioners. The energy conservation of the system provides more space for equipment choices.


Industrial air conditioning, chemical fiber industrial air conditioningchemical fiber industry refrigeration, textile industrial air conditioning, dust-free workshop coolingventilation pipeline, cooling tower, freezer and other air conditioning units and accessories.


Jiangsu Jincheng Air Conditioning Engineering Co., Ltd. is a comprehensive manufacturer of special air-conditioning equipment design, production, installation, and commissioning of clean room, electricity, tobacco, civil air defense engineering, medical clean room, clean room, electricity, tobacco, civil air defense engineering, medical clean room. Mainly produce JCZK combined air conditioning unit, cooling tower, glass steel ventilated galvanized sheet pipe, stainless steel pipe, polyurethane ventilation pipe and air conditioning accessories, Jincheng air conditioner is wide, the type, the unique model, superior performance, and user Favused.


Keyword:
ADD:No. 18, Rongguang Road, National High-tech Park, Yancheng City, Jiangsu Province Phone: 0086-13705113637 Tell: 0086-0515-88809180 Fax: 0086-0515-88809181 E-Mail: jsjckt@126.com
Copyright ? 2018 All rights reserved
Copyright Jiangsu Jin Cheng Air Conditioning Engineering Co.,Ltd 技術(shù)支持:中國(guó)丙綸網(wǎng)