[Common problems of air conditioner compressor]
Release date:[2023/12/14] Is reading[122]次

The compressor works, but the air supply is not cold enough

1, the outdoor environment temperature is too high. The capacity of the air conditioner is limited and cannot be cooled to the desired comfortable temperature.

2, the condenser ash is serious, the ventilation is not smooth, the heat dissipation effect is poor, resulting in the cooling capacity of the air conditioner.

3. Installation position. Outdoor units are exposed to the sun; The position of the indoor unit is too high, too low and the deflection Angle, resulting in poor circulation of cold air.

4. The refrigeration circulation system is blocked. After the capillary tube or filter dryer is blocked, the liquid refrigerant flowing into the evaporator is reduced, and the cooling capacity is reduced.

5, the electromagnetic four-way reversing valve, reversing valve solenoid coil, cold and hot reversing switch is faulty, resulting in poor cooling effect or no cooling.

The compressor stops as soon as it starts

1, the external machine sun, ventilation blocked, etc., condensation effect is not good, exhaust pressure is too high and shut down.

2, abnormally high voltage or low voltage, the compressor can not start, the current is too large, the overload protector action and stop.

3. Wiring error, insufficient power grid capacity, large line voltage drop, and overcurrent cause shutdown of the overload protector operating surface.

4. The outdoor temperature is too high. The condensing pressure rises, the compressor is overloaded, and the protector automatically cuts off the power supply and stops. If the air conditioner is operated normally, the wind speed can be placed in the medium-cold or low-cold gear to reduce the refrigeration load and make the air conditioner continue to operate.

5, capacitor contact is poor or damaged, so that the compressor can not operate normally


Declaration: The content and template of this article are organized from the network, and the copyright belongs to the original author; If there is infringement, please inform in time and contact to delete.


Industrial air conditioning, chemical fiber industrial air conditioningchemical fiber industry refrigeration ,textile industrial air conditioning dust-free workshop coolingventilation pipeline, cooling tower, freezer and other air conditioning units and accessories.

Jiangsu Jincheng Air Conditioning Engineering Co., Ltd. is a comprehensive manufacturer of special air-conditioning equipment design, production, installation, and commissioning of clean room, electricity, tobacco, civil air defense engineering, medical clean room, clean room, electricity, tobacco, civil air defense engineering, medical clean room. Mainly produce JCZK combined air conditioning unit, cooling tower, glass steel ventilated galvanized sheet pipe, stainless steel pipe, polyurethane ventilation pipe and air conditioning accessories, Jincheng air conditioner is wide, the type, the unique model, superior performance, and user Favused.



Keyword:
ADD:No. 18, Rongguang Road, National High-tech Park, Yancheng City, Jiangsu Province Phone: 0086-13705113637 Tell: 0086-0515-88809180 Fax: 0086-0515-88809181 E-Mail: jsjckt@126.com
Copyright ? 2018 All rights reserved
Copyright Jiangsu Jin Cheng Air Conditioning Engineering Co.,Ltd 技術(shù)支持:中國丙綸網(wǎng)