[Jincheng teaches you three ways to solve the problem of excessive energy consumption in the textile industry air conditioner!]
Release date:[2018/12/4] Is reading[774]次

The textile industry air conditioners need to consume a lot of energy when they are used. Especially in the summer peak period, how to make the textile industry air conditioners become more energy-efficient when used, it becomes a top problem that the textile factory owners need to solve. Today, Jin has become a small coup for everyone to bring energy-saving to air-conditioning in the textile industry, hoping to help everyone.


I. Textile Industry Air Conditioning - Starting from the actual energy situation, formulating reasonable air conditioning standards

    

The air conditioning standards in the workshop are closely linked to energy consumption. At the current level, for every 1°C reduction in the temperature of the summer workshop, it is necessary to consume more than 10% of the cooling capacity. Therefore, proper relaxation of the air conditioning standard means that the cooling capacity in summer can be greatly saved. The humidity standard of the textile factory mainly depends on the process requirements, and the relative humidity of the air is roughly controlled within the range of 50% to 80%. Summer is the peak period of air conditioning energy consumption. It is feasible to set the workshop temperature below “Southern 30°C/North 28°C”; the temperature is best controlled at 22~25°C in spring and autumn, and the winter can be based on the process characteristics of the product. It is set at 18~25°C as appropriate.


Second, the textile industry air conditioning - the implementation of variable air volume adjustment

    

The so-called variable air volume adjustment, in simple terms, is based on changes in the load of the shop, correspondingly increase or decrease the amount of ventilation. The variable air volume adjustment is mainly controlled by the fan, adjusting the air inlet blades and changing the blade angle. From the perspective of energy saving, it is most advantageous to use the fan speed control method.

    

1. For the worsted and woven fabric workshops with high air conditioning requirements and large capacity, rectification slip speed regulation, cascade speed regulation, voltage regulation speed regulation and frequency conversion speed regulation can be used. Generally, pressure regulation is adopted. Speed and frequency control are mostly. The voltage regulation speed is lower, but the motor needs to be replaced; the frequency conversion speed regulation can be equipped with a frequency conversion device on the basis of the original motor, and the operation is stable, the fault is small, and the adjustment is easy, which is especially suitable for the transformation of the old factory.

    

2. For workshops with low air conditioning requirements and small capacity, a multi-speed motor or a simple method of changing the belt and adjusting the blades can be used.

    

3. Use efficient and energy-saving motors and fans.


Third, textile industry air conditioning - reasonable use of return air, control blower dew point


Reasonable use of return air not only stabilizes the temperature and humidity of the workshop, reduces production fluctuations, improves production quality, but also greatly reduces air conditioning energy consumption. Even in the transition period of spring, summer and autumn and winter, as long as the new and return air ratio and the use of circulating water spray washing air are regulated, the purpose of improving the air supply quality and saving energy can be achieved. Especially in the summer, as the outdoor wet bulb temperature increases, the amount of return air must increase accordingly, otherwise it will cause waste of cooling.

    

From the calculation formula of the cold load of the workshop and the cooling capacity of the air conditioner, it can be known that there is a close relationship between the temperature and humidity, the cooling load, the mixed air ratio and the dew point of the blower. Under normal circumstances, the smaller the dew point of the machine, the greater the amount of cooling required to spray the cooling air. The increase in the amount of return air reduces the enthalpy of the mixed air, and the required cooling capacity is also reduced.


Jiangsu Jincheng Air Conditioning Co., Ltd. is a comprehensive manufacturer specializing in the design, production, installation and commissioning of complete sets of air conditioning equipment for chemical fiber, textile, subway engineering, electronic workshop clean room, electric power, tobacco, civil air defense engineering and medical clean room. The products sell well in dozens of provinces and cities across the country, and are exported to overseas. Jincheng air-conditioning is your trustworthy brand! (Textile Industry Air Conditioner)


The textile industry air conditioner produced by Jiangsu Jincheng Air Conditioning Co., Ltd. is more professional and more worry-free, providing environmental temperature, humidity and cleanliness for the reliable operation of industrial products and process equipment.